Fungilab V-PAD Viscometer
The V-serie product range, with an extraordinary design and a state-of-the-art technology offers unique and innovative options for the users. The V-Pad is controlled through an intuitive App in a 8
Screen Data
- Selected speed rpm, S-1
- Selected spindle SP
- Viscosity reading cP, mPa·s, Pa·s, cSt, St, mm2/s
- Percentatge of full scale %
- Sample temperature ºC or ºF
- Shear Rate (with coaxial spindles, and L2C+L3C) SR s-1
- Shear Stress (with coaxial spindles and L2C+L3C) SS (N/m2,Pa, Dyne/m2
- Density (introduced by the user) (g/cm3, Kg/m3)
- On Tablet
- Precision: +/- 1% full scale of range
- Repeatability: 0.2
- Temperature Range : -40ºC to 300ºC, -40ºF to 572ºF
- Temperature Resolve : 0.1ºC
- Temperature Precision : +/- 0.3ºC
- Probe Model : PT100, Class A its supplied to 90 240VAC, 50/60Hz
Program features
- Created and edit Multiple Programs
- Store Programs for later use
- Choose between time to torque
- Time to stop
Data Warehouse
- Store the experiment result realized in one complite database
- Users are able to analyse and review the data saved the future samples
- Users can acces to the settings of the program for each experiment
Customization
- Created a customization speed list between 0,01 to 250 rpm
- Activate/desactivate control quality with “out of range” indikator alarms
Users can change the values of the acces
V- SERIESV-PAD
The V-serie product range, with an extraordinary design and a state-of-the-art technology offers unique and innovative options for the users. The V-Pad is controlled through an intuitive App in a 8” tablet Model and viscosity range cP (mPa.s)
(*) Low viscosity: The minimum viscosity when using a “L” range with standard spindles is 10 cP * For measurements < 10cP, its recommended to use in conunction with the low viscosity adapter (LCP or LCP/B) Ranges: – (L) Low for Viscosity – (R) Regular or Medium Viscosity – (H) High Viscosity Rase | ||||||||||||||||
Accecories
APM
Small Sample Adapter with circulation jacket (without TL or TR spindles) Sample volume (6.7 – 13 ml.) Compatible with Brookfield
APM/B
Small Sample Adapter without circulation jacket (without TL or TR spindles) Sample volume (6.7 – 13 ml.) Compatible with Brookfield
LCP
Low Viscosity Adapter with circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield
LCP/B
Low Viscosity Adapter without circulation jacket (with spindle) Sample volume (16 ml.) Compatible with Brookfield
THERMOSPHERE
Temperature control unit up to 300 ºC
PPR
Fast and convenient spindle coupleable system (optional)
Available in PPR (Push Plug and Release)
Model Code no. | Min cP | Max cP | Number of speeds |
VPAD L+RTD+PPR VP101003 | *1 | 6 M | 2600 |
VPAD R+RTD+PPR VP101002 | 25 | 40 M | 2600 |
VPAD H+RTD+PPR VP101001 | 200 | 320 M | 2600 |